Read the product identity, intended use, units and preparation together before accepting an application specification.

Two coats can describe different amounts of material: a thickness may refer to each coat or to both together. Those labels matter when checking a window return or comparing quotations. Use the exact product’s current technical instructions, and keep a public homeowner guide distinct from a complete installation specification.
Use the document linked to the product being quoted
The Decork Façade sheet linked from Diasen’s product page when checked on 30 October 2026 carries document code 24212004. An older PDF also appears in search results. Starting from the manufacturer’s current product page helps distinguish the document currently offered from an old copy that happens to rank well.
CorkSol’s public installation guide is a different kind of document. It explains what a homeowner can expect from SprayCork work, while its full technical-sheet download requests an email. The guide can support its stated application example, but detailed matters absent from it still need the applicable technical instructions. One manufacturer’s full sheet cannot fill the gaps in another manufacturer’s product.
Keep the product name and document version with the accepted proposal. If either changes before work starts, recheck the preparation and application requirements. A matching colour does not establish that the revised coating uses the same primer, layer thickness or drying sequence.
Find the intended use and what the coating contains
Diasen identifies Decork Façade as an outdoor finish. Its sheet describes cork particles, water-based resins and siloxanes, with a grain size of 0–1mm. That describes the material being spread or sprayed; it is not a sheet of insulation fixed to the wall. The binder holds the textured coating together, while the prepared background supports it.
Intended use is more specific than a list of backgrounds. The same document contains a plasterboard preparation entry, but its stated outdoor scope should still be respected. An indoor proposal needs an appropriate product and application instruction, rather than relying on that single material reference.
A sample should identify the actual coating and the surface below it. A generic textured board can help explain appearance, but it cannot verify the product composition or a measured coating thickness. Those come from the material schedule, instructions and application checks.

Read each coat figure with its unit
The Decork Façade sheet states approximately 2mm total thickness across two coats, with a combined yield of 0.90–1.20kg/m². These figures describe that named product’s arrangement; the mass is not specified as the amount for each coat. Dividing or doubling a number without reading its label can change the proposed work substantially.
CorkSol’s public guide describes two indoor coats and an optional separate plaster skim. Confirm the actual dimensions from the current specification for the proposed work rather than turning a public example into a universal setting-out figure. Products and indoor or outdoor arrangements should retain their own instructions.
These dimensions matter where the new surface meets a frame or trim. Ask whether a quoted thickness refers to an individual layer or the full coating, and whether an additional finish is included. If the instructions do not identify a figure as a wet or dry measurement, obtain clarification rather than adding that label yourself.
A drying figure includes the conditions beside it
Diasen’s application text requires the first layer to dry before the next and gives about 10 hours at 23°C and 50% relative humidity as its example. Its technical table gives approximately 8–10 hours between coats under those conditions. That is not a guaranteed overnight interval on an exterior wall in a different temperature or humidity.
The same sheet explains that the drying period changes with the conditions and amount applied. CorkSol likewise relates readiness for the next layer to temperature, humidity and air movement. A sheltered return, a sunny face and an occupied room can present different conditions on the same day.
The practical instruction is to assess readiness against the selected product’s requirements. A booking for the second visit cannot make an unfinished first coat ready. The work programme and temporary protection need to allow for that, including reassessment if weather affects an uncured exterior surface.
Scroll sideways to see the full table. Keyboard: focus the table, then use the arrow keys.
| Document and application | What the cited figure describes | What to keep with it |
|---|---|---|
| Decork Façade, exterior TDS 24212004 | About 2mm total; 0.90–1.20kg/m² across two coats | Named product, preparation and full application instructions |
| CorkSol public indoor guide | Two-coat stage; optional separate skim | Confirm dimensions and suitability in the current project specification |
| Decork Façade drying example | About 10h at 23°C/50%RH; table 8–10h between coats | First-layer readiness and actual conditions |
Preparation is part of the tested arrangement
A coat applied over an old painted wall is supported by that paint and the material below. If either is loose, adding a new layer does not restore the attachment. The assessment needs to distinguish the new coating’s bond from the condition of the retained background.
For painted old render, Diasen recommends an adhesion trial and sets out possible preparation within its own product range. Elsewhere it gives different instructions for smooth or non-absorbent surfaces. Those distinctions show why a general promise to prepare the wall should identify the actual work and materials.
The trial must represent the wall in question. A recently repaired smooth patch does not necessarily stand for an older painted area beside it. Record the preparation used and the location represented by the result. Appearance approval and adhesion assessment should remain identifiable decisions.
Match performance evidence to the question being asked
A material datasheet can contain several tests that answer different questions. Reaction to fire concerns a material’s behaviour in a fire test; it is not a stated period of fire resistance for an entire wall. Likewise, sound absorption and sound insulation are different properties. Any project requirement needs the relevant complete evidence interpreted for its actual construction.
A thermal material value also needs thickness and construction context before it can inform a wall assessment. It does not predict household bills on its own. Keep numerical savings, condensation remedies and whole-building outcomes out of the comparison unless the appropriate assessment actually supports them.
For a decorative project, the useful evidence may instead be background suitability, preparation and a representative texture trial. There is no need to convert a finish choice into a performance claim that was never part of the brief.
Separate a datasheet from a warranty
A technical sheet explains the product and its use; warranty terms define particular commitments and conditions. They may be related, but one should not be assumed to contain the whole of the other. Request the actual terms where cover is offered.
Ask who provides that cover and what records are needed. Keep installation information, accepted changes and any relevant maintenance advice together. That is more useful if a concern arises than a saved screenshot of a headline duration.
Connect the instructions to the work being bought
A quote should name the coating, the surfaces receiving it and the preparation for each. Include the masking, awkward returns and necessary reinstatement. Then compare the layer and drying requirements with the proposed sequence. This exposes missing work more clearly than comparing two prices for an unnamed spray finish.
Before application, resolve any uncertain product substitution or background with the responsible supplier and installer. Retain their specific advice with the document used for the job. That leaves a practical record for the work now and for any later repair to the same surface.

Questions and answers
Is a brochure enough to specify the work?
No. Use it to identify the product, then obtain the current technical instructions and supporting evidence needed for the actual application.
What if the datasheet is behind a download form?
Request the current document from the supplier or manufacturer. Until it is available, keep detailed requirements unresolved rather than replacing them with guessed values.
Sources and further reading
- Diasen Decork Façade technical data sheet, code 24212004Source checked: 30 October 2026
- CorkSol public installation guideSource checked: 30 October 2026
- CorkSol download catalogueSource checked: 29 October 2026
- British Gypsum system principles: partition interfaces, height and fire behaviourRelease/version: Relevant sections: 11 September 2023Source checked: 30 October 2026